Tweco 75XL Plus PAK Master Manuel d'utilisation
Page 16

INTRODUCTION
2-2
Manual 0-2807
6. Duty Cycle (Refer to NOTE)
NOTE
The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.
Ambient
Temperature
Duty Cycle
40%
65%
100%
Current
n/a
60 Amps 50 Amps
DC Voltage
n/a
104 vdc
104 vdc
PakMaster 75XLP Automated
Power Supply Duty Cycle
104° F
(40° C)
7. Cut Capacity (Mild Steel)
Production:
5/16 inch (7.9 mm)
Genuine:
3/4 inch (19.1 mm)
Severance:
1 inch (25.4 mm)
8. Pilot Circuitry
Capacitive Discharge (CD), Pulsed DC
9. Weight
64 lbs (29 kg) w/work lead
71 lbs (32 kg) w/work lead and 25' Torch & Lead
10. Overall Dimensions
19" (482 mm) High x 10.5" (267 mm) Wide x 24.8"
(630 mm) Long
Overall dimensions are with Handle, Gas Regulator/
Filter Assembly and Two Stage Air Filter installed.
B. Gas Regulator/Filter Assembly
Specifications
The following specifications apply to the Gas Regulator/
Filter Assembly only:
1. Gas regulator maximum gauge pressure
160 psi (11 bar)
2. Maximum input gas pressure
125 psi (8.6 bar)
3. Filter
Coalescent type filter
C. Two Stage Air Line Filter Specifications
The following specifications apply to the Two Stage Air
Line Filter Assembly only:
NOTE
The two stage air line filter is for use on systems
using compressed air.
1. Air Flow
15 scfm (425 lpm)
NOTE
Depending on the moisture in the air source the
weep drain on the bottom of the Filter should be
left open 1/4 turn at all times. The weep drain will
allow 10 scfh (10.7 lpm) of air to escape using 100
psi line pressure in the closed position. This will
allow water, oil and contamination to escape from
the filter.
2. Maximum input pressure
250 psi (17.2 bar)
3. Dew Point
10° to 35° F (-12° to 1.7° C) @ Atmospheric Pressure
4. Filtration
5 micron