INSTALLATION
3.17 Install Torch Valve
General Information
This assembly mounts as close as possible to the torch head. It accepts preflow, plasma, and shield gases from
the Gas Control Module and supplies these gases to the Torch.
Mounting
1.450”
36.83 mm
4.450”
113.03 mm
.261” Dia.
6.63 mm
Art # A-08433
1. Mount the Valve Kit as close as possible to the Torch. The valve kit can be mounted in any convenient
position, provided the outlet side (with two fittings) is closer to the torch than the inlet side (with three fittings
and a control cable connector).
2. Connect the Valve Kit outlets to the torch leads as shown.
Art # A-04761
Right-hand Thread:
To Torch Shield Gas fitting
Left-hand Thread:
To Torch Plasma Gas fitting
Do not remove brass plugs
Outlet Side