H. prepare the torch head – Tweco 300 Auto-Cut Manuel d'utilisation
Page 116
Advertising

Manual 0-4817 Auto-Cut 300
A-20
APPENDIX
G. Connect Control Cables for CNC, Remote Arc Starter, and GCM
1. Connect one end of each cable to the power supply.
2. Connect the other end of the CNC cable to the CNC device
.
3. The CNC cable shield must be attached to ground at the CNC end of the cable. Do not ground to the Plasma
Power Supply.
RETURN
SUPPLY
Art # A-04802
To CNC
To Remote Arc Starter
To Gas Control Module
Customer Wiring
Access Hole
H. Prepare the Torch Head
1. Remove the jumper on the torch head, as shown and discard or store separately.
Jumper
Art # A-07323
1
2
Discard
4
3