Installation, Ground – Regency Horizon HZ54EPV Large Gas Fireplace Manuel d'utilisation
Page 30

30
Regency Horizon HZ54EPV Foyer
à Gaz
installation
scHÉMaMe du filaGe
aVec le sYstÈMe proflaMe GtMf et un Ventilateur en option
NOTE: Wiring schematics for HZ54E (120 Volts),
plug-in fan circuit with speed control switch on wall.
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(for mobile home)
Star washer
Ground
Green
Neutral
Live
Black
Black
Black
Fan Thermodisc
(normally open)
Ground
120V AC
60 Hz
Fan
White
Black
Black
"Plug-in Fan" circuit supplied by Regency
Green
Fan
Black
Black
Convection Air Temperature Switch
(Thermodisc - normally open)
Power Cord
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
*Speed Control
Switch with
lead wires
(Regency)
Wire Nuts
Wire Nuts
14 AWG wire
14 AWG wire
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by stove fan only)
120 Volts
60 Hz
Copper Ground
White (Neutral)
Black (Hot)
Black (Hot)
Green (Ground)
Black (Neutral)
~
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
*Speed Control
Switch with lead wires
Wire Nuts
14 AWG wire
*Wire Clamp
120 Volts
60 Hz
Copper Ground
White (Neutral)
Black (Hot)
Wire
Black
White
Ground
*Receptacle Box
inside stove
~
*Receptacle
(dedicated use
by unit fan only)
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
caution: ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Thermodisc
Green
Green (Ground)
White (Neutral)
Black (Live)
Black
White
White
(*by others)
(*by
others)
Black
Black
Ground for
mobile home
120 VAC
60HZ
(*by others)
Fan
Rotary Speed
Control
ON
OFF
Fan
(*Supplied
by others
- install
according to
local code)