Installation – Regency Bellavista B41XTE Large Gas Fireplace Manuel d'utilisation
Page 20

20
Regency B41XT Foyer à gaz à évent direct
INSTALLATION
Description
Simpson
Direct Vent Pro
®
Selkirk
Direct Temp™
Metal-Fab™
Sure Seal
ICC Excel
Direct
Attic Insulation Shield 12”
58DVA-IS
N/A from FPI
N/A
N/A
N/A
High Wind Vertical Cap
58DVA-VCH
N/A
N/A
TM-5VT
High Wind Horizontal Cap
N/A
N/A
N/A
TM-5DHT
Horizontal Square Termination Cap
N/A
5DT-HHC
5DHT
TM-5HT
Vertical Termination Cap
N/A
5DT-HVC
5DVT
TM-5VT
Storm Collar
58DVA-SC
5DT-SC
5DSC
TM-SC
Restrictor Disk
58DVA-RD
N/A
N/A
TM-5DS
Colinear Flex Connectors
N/A
N/A
N/A
N/A
Adjustable Flashing 0/12-6/12
58DVA-F6
5DT-AF6
5DF
TF-5FA
Adjustable Flashing 6/12-12/12
58DVA-F12
5DT-AF12
5DF1-2
TF-5FB
Vinyl Siding Standoff
58DVA-VSS
5DT-VS
5DVS
TM-VSS
Vinyl Siding Shield Plate
N/A
5DT-VSP
N/A
N/A
Snorkel Termination 14”
58DVA-SNK14
N/A
N/A
TM-5ST14
Snorkel Termination 36”
58DVA-SNK36 (N/A - FPI)
N/A
N/A
TM-5ST36
Basic Horizontal Termination Kit (A)
N/A
5DT-HKA
N/A
N/A
Horizontal Termination Kit (B)
58DVA-KHA
5DT-HKB
N/A
N/A
Vertical Termination Kit
58DVA-VHA
5DT-VKC
N/A
N/A
FPI
946-604/P
Simpson Direct Vent -Vent Guard (Optional)
946-623/P
AstroCap XL Horizontal Cap
770-994
Rigid Pipe Adaptor (Must use with all rigid piping)
946-506/P
Vent Guard (Optional)
946-606
Starter collar reducer 5” x 8” to 4” x 6-5/8”
946-625
Vinyl Siding Standoff - AstroCap XL
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
5” x 8” Venting
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Run (X)
Rise (Y)
0” (0mm)
5-11/16” (144mm)
15-5/16” (389mm)
Simpson Direct Vent Pro: www.duravent.com
6” (152mm)
8-13/16” (224mm)
18-7/16” (468mm)
Selkirk Direct-Temp: www.selkirkcorp.com
9” (229mm)
10-15/16” (278mm)
20-9/16” (522mm)
Metal-Fab Sure Seal: www.mtlfab.com
12” (305mm)
13” (330mm)
22-11/16” (576mm)
Industrial Chimney Company: www.icc-rsf.com
24” (610mm)
21-7/16” (697mm)
31-1/16” (789mm)
Note: Horizontal runs of vent must be level, or have a 1/4”
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.
36” (914mm)
29-13/16” (757mm)
39-7/16” (1002mm)
48” (1219mm)
38-1/4” (972mm)
47-7/8” (1216mm)
L676 & L900 DIRECT VENT FIREPLACE
• A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
• Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.
IMPORTANT NOTE
Note: Mettre les conduits d’évacuation horizontaux au niveau ou les installer de façon à ce que leur élévation ne dépasse pas ¼ pouce par pied de conduits jusqu’à la sortie.
S’assurer qu’aucune section du système d’évacuation n’est dirigée vers le bas. Une inclinaison descendante peut provoquer des hausses de température et comporter
un risque d'incendie.