Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light with match

No gas flow .

Obstruction of gas flow .

Spider webs or insect nest in venturi .

Burner ports clogged or blocked .

Check if LP cylinder is empty .

Clear burner tubes .

Clean venturi .

Clean burner ports .

Irregular flame pattern, flame does not run the full
length of burner.

Burner ports are clogged or blocked .

Clean burner ports .

Flame is yellow or orange

New burner may have residual manufacturing oils .

Spider webs or insect nest in venturi .

Food residue, grease or seasoning salt on burner .

Burn grill for 15 minutes with the lid closed .

Clean venturi .

Clean burner .

Flame blow out

High or gusting winds .

Low on LP Gas .

Turn front of grill to face wind or increase flame height .

Replace LP cylinder .

Flare-up

Grease buildup .
Excess fat in meat .
Excessive cooking temperature .

Clean grill .
Trim fat from meat before grilling .
Adjust (lower) temperature accordingly .

Persistent grease fire.

Grease trapped by food buildup around burner system .

Turn knobs to “LOCK OFF POSITION .” Let fire burn out . Leave lid
in closed position and let fire burn out . After grill cools, remove
and clean all parts .

Flashback (fire in burner tube(s))

Burner and/or burner tube is blocked .

Clean burner and/or burner tube .

Inside of lid is peeling-like paint peeling

The lid is porcelain coated, not paint .

Baked on grease buildup has turned to carbon and is flaking off .
Clean thoroughly .