Operating instructions, Installing natural gas line, Checking for leaks – Blue Rhino GBC956W1NG-C Manuel d'utilisation

Page 9: Operating main burners, Connect natural gas line, Disconnect natural gas line

Advertising
background image

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

page no.

9

Operating Instructions

Checking for Leaks

Burner Connections

1. Make sure the natural gas line is securely fastened

to the burner and the main gas natural gas line.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.

WARNING: Failure to inspect this

connection or follow these instructions

could cause a fire or an explosion

which can cause death, serious bodily

injury, or damage to property.

2. Please refer to diagram for proper installation.

(Figure 1 and 2)

3. If the burner pipe does not rest flush to the orifice,

please contact 1.800.762.1142 for assistance.

Gas Line Connection

1. Make 2-3 oz. of leak solution by mixing one part

liquid dishwashing soap with three parts water.

2. Make sure control knobs are “OFF”. (Figure 3)
3. Turn “ON” natural gas main valve.
4. Spoon leak check solution at all “X” locations

(Figure 4)
a. If any bubbles appear turn natural gas line valve

to “CLOSED”, reconnect and re-test.

b. If you continue to see bubbles after several

attempts, turn natural gas line valve to “CLOSED”
and disconnect natural gas line and contact
1.800.762.1142 for assistance.

c. If no bubbles appear after one minute turn natural

gas line valve to “CLOSED”, wipe away solution
and proceed.

Operating Main Burners

First Use

1. Make sure all labels, packaging and protective films

have been removed from the grill.

2. Remove manufacturing oils before cooking on this

grill for the first time by operating the grill for at
least 15 minutes on “HIGH” with the lid closed. This
will “heat clean” the internal parts and dissipate
odors.

Lighting

1. Open lid.

Attempting to light the burner with the

lid closed may cause an explosion!

2. Make sure there are no obstructions of airflow to

the burners. Spiders and insects can nest within
and clog the burner / venturi tube at the orifice. A
clogged burner tube can lead to a fire beneath the
appliance.

3. All control knobs must be in the “OFF” position.

(Figure 3)

4. Turn natural gas line valve to “OPEN”.
5. Select burner to light. Push and turn control knob

counterclockwise to “HIGH”.

6. Press the electronic igniter button and hold for 5

seconds to light burner.

7. If ignition does not occur in 5 seconds, turn burner

control knob “OFF”, wait 5 minutes, and repeat
lighting procedure.

8. If igniter does not light burner, use a lit match

secured with the lighting rod provided to light
burners manually. Access the burners through the
cooking grid and heat plates. Position the lit match
near side of the burner. (Figure 5)

Important: Always use the lighting rod provided when
lighting burners with a match.
9. After lighting, observe the burner flame, make sure

all burner ports are lit and flame height matches
illustration. (Figure 6)

Note: Each burner lights independently - repeat steps
5-9 for the other burners.

Figure 1

Burner
venturi pipe

Valve Soft Pipe
Connection

Gas Valve
with Orifice

Main Burners

Figure 2

Gas
Connection

Gas Valve with
Orifice

Valve
Soft Pipe
Connection

Side Burner

Burner
venturi
pipe

Figure 3

Figure 4

Figure 5

Figure 6

Burner

Flame

Slight

Yellow

Slight

Blue

Dark

Blue

Installing Natural Gas Line

Installation should be done by a qualified service person.

CAUTION: If young children are in the area, a locking valve should be
considered.

Connect Natural Gas Line

Before connecting, be sure that there is no debris caught in
the head of the natural gas line, head of the grill natural gas
line or in the head of the burner and burner ports.
Connect grill natural gas line to natural gas line.

Disconnect Natural Gas Line

Before disconnecting make sure the natural gas line valve is “OFF”.
Disconnect grill natural gas line from natural gas line.

Advertising