Sunlight Supply Grozone Control CY3 Digital Cyclestat with Day/Night Sensor and Bargraph Display Manuel d'utilisation
Step 1 set values, Step 2 2 connect your equipment, Cyclestat-3 digital timer

STEP 1
SET VALUES
Connect your timer and click knob to view in sequence :
• DAY ON time
• NIGHT ON time
• DAY OFF time
• NIGHT OFF time
When DAY ON time indicator is steady lit (not blinking), the display
shows day on time ranging from 5 seconds to 60 minutes (left side scale).
When NIGHT ON time indicator is steady lit (not blinking), the display
shows night on time ranging from 5 seconds to 60 minutes (left side scale).
When DAY OFF time indicator is steady lit (not blinking), the display
shows day off time ranging from 1 minute to 12 hours (right side scale).
When NIGHT OFF time indicator is steady lit (not blinking), the display
shows night off time ranging from 1 minute to 12 hours (right side scale).
STEP 2 2
CONNECT YOUR EQUIPMENT
Connect your pump or other equipment in the 120V output plug in front of
your timer. You’re set !
BLINKING INDICATOR AND TIME COUNTDOWN
A blinking indicator tells you which time is currently running.
Countdown is shown on display at all times during normal cycle operation.
Example 1
Example 2
DAY ON Indicator is blinking.
NIGHT OFF Indicator is blinking.
Display bar “15” is lit (left scale).
Display bars “30” and “40” are lit (right scale).
DAY is detected and
NIGHT is detected and
the pump is currently working.
the pump is NOT working.
ON time will run for 15 more seconds
OFF time will run for 35 more minutes
before it switches to OFF time.
before it switches to ON time.
CYCLESTAT-3
DIGITAL TIMER
CY3
.
.
Rev. 1.0
DAY ON Time
Indicator
NIGHT ON Time
Indicator
NIGHT OFF Time
Indicator
DAY OFF Time
Indicator
Click knob to select and
turn to set values
The bargraph display
shows a remaining
time of 35 minutes.
120V
OUTPUT
PLUG
BARGRAPH DISPLAY
Use SCALE on LEFT SIDE for ON times
(5 seconds to 60 minutes)
Use SCALE on RIGHT SIDE for OFF times
(1 minute to 12 hours)
PHOTOCELL
DAY AND NIGHT DETECTION
The photocell detects a NIGHT
condition when it senses darkness for a
minimum period of 8 seconds.
The photocell detects a DAY
condition when it senses light for a
minimum period of 8 seconds.
DISABLING OPERATION
In order to disable DAY or NIGHT
operation, set corresponding ON time to
“zero” - turn knob counter clockwise
until all bars are OFF when setting DAY
ON or NIGHT ON times.
BOTTOM BAR IS BLINKING
The bottom bar of display is flashing at
the end of a cycle. The bar will flash for
2 seconds at the end of an ON time, and
for 30 seconds at the end of an OFF time.
Please visit
www.grozonecontrol.com
for application notes and
new product updates.
The bargraph display
shows a remaining
time of 15 seconds.