Machine set-up – NaceCare Solutions ETB1120 Manuel d'utilisation
Page 10

10
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED
BEFORE MAKING ANY ADJUSTMENTS
!
!
Fitting the brushes
Featuring the Nulock brush system.
The brush is simply pushed and twisted to lock, making fitting and removal a simple process.
The Pad is retained using Numatic’s own PadLoc system. (Ask your supplier for details)
Only use manufacturer supplied brushes / pads.
ETB 1120 requires a 20’’ brush or pad
Fitting and lowering the Floor Tool
The floor tool has been designed for quick fitting, allowing easy squeegee blade replacement.
Raise the floor tool for transit or
lower for cleaning operation using
the lifting handle fitted to the back
of the machine (Fig 20).
We are now ready to set the
controls to suit the cleaning
conditions.
Before any settings can be
applied, ensure the brush deck is
lowered.
Safety gloves are recommended for the changing of used brushes.
Note:
It is easier to fit the floor-tool if the weight of the machine is resting on the brush. Ensure the brush is fitted first.
Machine Set-Up
Fit the brush /pad to the drive chuck,
twist to lock the brush
(Fig 14) / pad in place (Fig 15).
Tipping the Brush Deck
To tip the deck into the down position
(Operating mode) Press in the brush
deck locking bar (Fig 16) and rotate the
brush deck (Fig 17).
To change to brush deck up position,
(Transit mode) simply lift the deck and
the sprung loaded locking bar will active
to hold the deck up.
Fig 15
Fig 17
Fig 20
Fig 19
Fig 18
Fig 16
Fig 14
Fit the floor tool and retain using
the detent Pin (Fig 18).
The lifting strap is held by a
detent pin (Fig 19).