Napoleon Fireplaces Vector 45 - LHD45 Manuel d'utilisation
Page 29

W415-0834 / E / 06.13.13
29
EN
INSIDE
CHASE
OUTSIDE
CHASE
73 1/2"
1867mm
MIN
BACK WALL OF CHASE / ENCLOSURE
(INCLUDING ANY FINISHING MATERIAL)
46 3/4" 1187mm
52"
1320mm
20 1/8"
511mm
20 1/8"
511mm
46 3/4" 1187mm
46 3/4" 1187mm
2" 51mm
* When constructing the enclosure allow for fi nishing material thickness to maintain clearances.
** HORIZONTAL VENT SECTIONS:
A minimum clearance of 2” (50.8mm) to the top and 1” (25.4mm) to the
sides and bottom of the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections
within enclosures require a minimum clearance of 6” (152.4mm) at the top of the vent pipe, see “MINIMUM
CLEARANCE TO COMBUSTIBLE ENCLOSURES” section. Use fi restop spacer W010-1777 (supplied).
** VERTICAL VENT SECTIONS:
A minimum of 1” (25.4mm) all around the vent pipe on all vertical runs
to combustibles is required except for clearances in appliance enclosures. Vertical vent sections within
enclosures require a minimum clearance of 2” (50.8mm) around the vent pipe. Use fi restop spacer W500-0096
(not supplied).
FRAMING
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES FROM
APPLIANCE AND VENT SURFACES:
ROUGH OPENING
HEIGHT
WIDTH
DEPTH
TO
CEILING
FROM
BASE OF
APPLIANCE
TO CEILING
FROM TOP
OF
APPLIANCE
OPENING
SIDE
WALL
TO
COMBUSTIBLE
FINISHING
ABOVE
APPLIANCE
TOP OF
VENT
PIPE
SIDES
AND
BOTTOM
OF VENT
PIPE
REAR
& SIDE
STAND-
OFFS
41 ¼”
(1047.8mm)
46 ¾”
(1187.5mm)
20 ¹/
8
”
(511.2mm)*
56”
(1422.4mm)
30 ¹¹/
16
”
(779.5mm)
2”
(50.8mm)
14”
(355.6mm)
2”
(50.8mm)**
1”
(25.4mm)**
0”
(0mm)