Doyon JAOP10 Manuel d'utilisation
Page 11

A-12
The customer must install a manual shut off valve at the end of the gas supply pipe near the
burner which is approved by the American Gas Association Standard in the United States and
with the Canadian Gas Association in Canada.
Exhaust: A draft hood is provided with the unit and it must be used when the chimney is
directly connected to a gas vent pipe. The exhaust pipe must be certified for use of
gases.
Clean the air contained in the gas supply pipe at the installation to insure a successful firing on
the first try. The gas pipe sealing compound tightness must be verified using a solution of water
and soap prior to firing the unit.
WARNING
Make sure not to obstruct the overpressure opening on the gas regulator.
NOTE:
If there's any modification done to the system or change of the type of gas used, make
sure that the regulator pressure of the burner is adjusted as recommended in this
manual.
2. To the electrician
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
WARNING
The electrician must make sure that the supply cable does not come in contact with
the oven top which becomes hot.
3. To the plumber
This equipment is to be installed to comply with the applicable federal, state or local plumbing
codes.
Connect the steam system (1/4 NPT) to the cold water distribution network.
We highly recommend a water softener to eliminate minerals in the water. We suggest you to use
CUNO # CFS6135 (Doyon part number PLF240).
WARNING
Do not adjust the needle valves, it has been done at the factory.