STANDARD AIR CONTROLS 10-2100-(-)(IMP) & 10-2200-(-)(IMP)
Material
White ABS/grey ABS/chrome-plated ABS.
Dimensions
Hole size Socket size
10-2200-(-)
1 1/16”
20 mm
10-2200IMP:
1 1/16”
½”
10-2100-(-)
1 11/16”
32 mm
10-2100IMP:
1 11/16”
1”
Important
Follow the directions for installation and connection. We reserve the right to change the product and the
manual without notice.
Installation
1. Before drilling a hole for air control, maker sure the surface is flat, this will help
assure the best seal.
2. Drill a hole according to recommended hole size.
3. Remove nut (4) and gasket (3) from air control.
4. Place silicone on backside of flange of air control body and install air control
through hole in tub/spa.
5. Place gasket (3) onto body (2) on the outside of the tub/spa.
6. Hand tighten nut (4) onto body (2).
7. Remove excess silicone from around flange of air control and surface of tub/spa.
8. Glue appropriate size hose onto bottom of air control.
Warning
Do not use any type of petroleum based lubricant, they will damage the product.
49-10-2100CEC