Indesit KN6M6SA(W)-FR Manuel d'utilisation
Page 18

18
GB
Table 1
Liquid gas
Natural gas
Thermal power
kW (p.c.s.*)
Capacity*
g/h
Burner Diameter
(mm)
Nominal Reduced
Bypass
1/100
(mm)
Nozzle
1/100
(mm)
*** **
Nozzle
1/100
(mm)
Capacity*
l/h
Rapid (Large)
(R)
100 3.00 0.70 41 86 218 214 116 286
Semi-rapid
(Medium) (S)
75
1.90 0.40 30 70 138 136 106 181
Auxiliary
(Small) (A)
55 1.00
0.40
30
50
73 71 79 95
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
S
R
A
ø 180
TEC H NICA L DA TA
Oven d im en sions
(Lx DxH )
32x43,5x43 cm
Volum e
56 l
U se ful
m easurem ents
relating to th e oven
com partment
width 42 cm
depth 46 cm
height 8,5 cm
Pow er s up ply
voltag e an d
freq uency
see d ata plate
B urners
may be adapted for use with any type of
gas shown on the data plate
EN ERG Y LA BEL
Directive 2002/40/E C on the lab el of
electric ovens. Stand ard EN 50304
Energ y consumption for Natural
convection – heating mod e:
Static
;
Energ y consumption for Forced
convection – heating mod e:
Fan
Oven;
EC Directives: 06/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments –
04/108/EC d ated 15/12/04
(Electromagnetic Compatibility) and
sub seq uent amendments –
93/68/EE C dated 22/07/93 and
sub seq uent amendments –
2002/96/EC.
1275/2008 Stand-b y/ O ff mode
WARNING! The glass
lid can break in if it is
heated up. Turn off all
the burners and the
electric plates before
closing the lid.
KN6M6SA/FR
KN6M66SA/FR
Table of burner and nozzle specifications