apx

1 =

0.94

5

0.3 = 0.23

apx

1 =

.037

5

0.3 = .009

apx

3 =

0.94

5

2 = 0.59

apx

3 =

.037

5

2 = .023

apx

4 =

0.94

5

3 = 0.73

apx

4 =

.037

5

3 = .029

apx

5 =

0.94

5

4 = 0.84

apx

5 =

.037

5

4 = .033

apx

6 =

0.94

5

5 = 0.94

apx

6 =

.037

5

5 = .037

apx

2 =

0.94

5

1 = 0.42

apx

2 =

.037

5

1 = .017

nap = 6

1 = 0.3

2 =1

n = x-1

5. Référence technique

1ère passe, pénétration

= 0.23 mm

= .009 pouce

2ème passe, pénétration

0.42 – 0.23 = 0.19 mm

.017 – .009 = .008 pouce

3ème passe, pénétration

0.59 – 0.42 = 0,17 mm

.023 – .017 = .006 pouce

4ème passe, pénétration

0.73 – 0.59 = 0.14 mm

.029 – .023 = .006 pouce

5ème passe, pénétration

0.84 – 0.73 = 0.11 mm

.033 – .029 = .004 pouce

6ème passe, pénétration

0.94 – 0.84 = 0.10 mm

.037 – .033 = .004 pouce

Pas 1.5 mm
a

p

= 0.94 mm (.037 pouces)