CONNECTING THE CYLINDER
IF CYLINDERS ARE USED TO SUPPLY THE HEATER, NO CYLINDERS SMALLER THAN 100
LB CAPACITY SHALL BE USED. THESE CYLINDERS MUST SUPPLY A VAPOUR
WITHDRAWAL ONLY.
1.) ALL CYLINDER CONNECTIONS MUST BE MADE USING A WRENCH TO TIGHTEN THE
POL FITTING.
2.) BE SURE THAT THE CYLINDER VALVE IS IN THE CLOSED POSITION WHEN
CONNECTING OR DISCONNECTING THE CYLINDER.
3.) PROPER PROCEDURE FOR GAS LEAK TESTING: A SOAP AND WATER SOLUTION
MUST BE APPLIED TO ALL CONNECTIONS IN ORDER TO LEAK CHECK THE SYSTEM.
4.) THE HOSE ASSEMBLY MUST BE VISUALLY INSPECTED PRIOR TO EACH USE OF
THE HEATER.
THE GAS MUST BE TURNED OFF AT THE PROPANE SUPPLY CYLINDER(S) WHEN THE
HEATER IS NOT IN USE. WHEN THE HEATER IS TO BE STORED INDOORS, THE
Nozzle
N/A
5.5 GPH X 60 B
Pump Pressure
N/A
160 PSI
GPH
N/A
7.6 GPH
Fuel
NG or LP
No. 1 or No. 2 /
Kerosene or
Furnace Oil
Head Setting
10.6
5
Air Setting (Beckett-
Shutter/Band) (Riello Air
Gate)
10/5
10/3
APPROVAL AGENCY
OMNI
OMNI
DRY WEIGHT (lbs)
2000
2000
Dimensions
111" X 33.25" X 50"
111" X 33.25" X
50"
FLUE SIZE
8”
8”
Certification File #
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com