CAMPO EQUIPMENT BLAZE 700 D/G Manuel d'utilisation
Page 9

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS ABLE IS TO RECEIVE 1 PHASE OR 3 PHASE POWER.
208V-240V SUPPLY MUST BE AVAILABLE.
INSTALLATION
Power Supply
Single phase operation use L1 (RED) and L2 (BLACK) plus green for ground.
Three phase operation use L1 (RED), L2 (BLACK) and L3 (WHITE) plus green for ground.
BLAZE 700 D/G
Power Cords for Single Phase
upto 100' 3 # 12
upto 200' 3 # 10
upto 300' 3 # 8
BLAZE 700 D/G
Power Cords for Three Phase
upto 100' 4 # 12
upto 300' 4 # 10
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT.
ELECTRICAL SYSTEM
BLAZE
700 D/G
Volts-Hertz-Phase
220-60-1 or
3
Full Load (Amps) (1PH OR 3PH)
16 or 8.5
Max fuse size (Amps) (1PH OR 3PH)
with time delay
20 or 10
The electrical grounding of the heater shall be in compliance with the National Electrical Code, ANSI/NFPA
70, or the CSA C22.1, Canadian Electrical Code, Part I
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
Tel: (905) 793-2525 | Fax: (905) 793-8768
P a g e
| 9