Name of parts (see fig.a) – MAX AKHL1250E Manuel d'utilisation
Page 12

12
2. NAME OF PARTS (See Fig.A)
Description of Functions of Key Components
1
Power switch
Turns on or off the power supply
2
Pressure-Reduction valve adjust-
ment handle (H) (Orange cap)
Intended for exclusive use with the
tool. It adjusts
the operating pressure of the
tool.
3
Pressure-Reduction valve adjust-
ment handle (L) (Yellow cap)
Adjusts the pressure supplied to the general-purpose
nailers and pneumatic tools (operating air pressure
120 psi (8.3 bar) maximum).
4
Pressure gauge in the tank
Indicates pressure in the tank. The pressure increases
up to 500 psi (34 bar).
5
Pressure gauge for indicating the
set reduction valve pressure (2
gauges)
It indicates the set pressure on the pressure-reduction
valves (H) and (L).
(355 psi (24.5 bar) maximum on the H side and 120 psi
(8.3 bar) maximum on the L side.)
6
High pressure air chuck (for MAX
tools)
It connects the MAX
air hose for the
tools.
7
General-purpose air chuck (for reg-
ular pressure tools)
It connects the air hose for the general-pressure nailers.
Fix the General-purpose air chuck in this nipple:
NPT 1/4" (for regular pressure tools). Ask your dealer or
an authorized service facility to fix it.
8
Drain cock
It drains compressed air and water, Drain once when the
work is finished or more a day.
9
Power plug
It is usable with a triode ground outlet.
0
Control panel
It allows switching the mode between Normal, High Pow-
er and Quiet. (See Fig.B) For details of the LEDs and
switches on the Control panel, see "Control Panel" on
page 13.
• Current consumption is reduced in the operation in
Quiet mode.
a
Air tank
b
Rubber foot
c
Power cord
d
Grip for two-handed carry