· Insulation is too close to fixture

· Remove insulation from around module (at least 3")

Check for any visible damage to the lamp or frame-in module. If they seem in good condition, locate the problem in

the

following list of possible causes and corrective actions.

GOTHAM ARCHITECTURAL DOWNLIGHTING

A DIVISION OF ACUITY LIGHTING GROUP , INC.

1400 Lester Road Conyers Georgia 30012

P 800 315 4982 F 770 860 3129

www.gothamlighting.com

INSTALLATION INSTRUCTIONS

Elevations

®

Performance Decorative Pendant

PDPA, PDPF

Upon receipt, thoroughly inspect for any

freight damage which should be brought to

the attention of the delivery carrier. Compare
the catalog description listed on the packing

slip with the label on the carton to ensure you
have received the correct merchandise.










®








IMPORTANT SAFETY INFORMATION

For Your Protection, Read Carefully

SAVE THESE INSTRUCTIONS

Direct Mount (PDPA or PDPF)

I. Ground Prep

1. Temporarily remove top cap and any round decorative piece to expose

support bracket.

2. Removing socket assembly from box, attach socket cup to reflector (per trim

instructions).

3. Route socket conductors through center hole on exposed support bracket.

4. Route conductors through top cap, replace the top cap, leaving screws

protruding 1/2 in. through keyholes (See Figure 1A).

5. Separate j-box pan from canopy by loosening the (3) side screws. Twist apart

to separate. VERIFY THAT THE ROUND DECORATIVE ELEMENT (IF RE-

QUIRED) IS ON PRIOR TO CONTINUING!

6. Route socket conductors from fixture through canopy piece hole and place

canopy over extended screws on fixture top (See Figure 1B).

7. Adjust canopy piece and fixture cap until both screw heads are fully captured

on both parts. Tighten both screws in position. SCREWS MUST BE COM-

PLETELY FORWARD IN KEYHOLES FOR FIXTURE TO BE CENTERED! Adjust if

necessary.

II. Ceiling Installation

8. Hang mounting pan by routing j-box wires through back of pan, and using

either 3.5 or 4.5 inch key holes, secure to j-box (See Figure 1C).

9. Hook the safety chain to the canopy's support tab to suspend the entire

assembly. Make all required electrical connections using wire-nuts.

10.

!

WARNING! Possible falling hazard and risk of serious injury.

Gather both cord and socket leads into tie strap strain relief so that a

minimum of two inches of cord conductors with socket conductors are pulled

inside tie strap. Make connections with wire nuts. Pull tie strap tight enough

to strain relieve all connections. Trim excess strap material (See Figure 1D).

11. Tighten screws. INSTALLATION COMPLETE.


1. Electric current can cause painful shock

or serious injury unless handled properly.
For your safety, always remember the fol-

lowing:

Turn off the power supply.

Ground the fixture to avoid potential

electrical shocks.

Do not handle an energized fixture or

energize any fixture with wet hands,

when standing on a wet or damp

surface, or in water.

Double check all electrical connections

to be sure they are tight and correct.

2. Specific safety information concerning

lamps:







Figure 1A

TROUBLE SHOOTING CHART










Figure 1B

Match wattage of fixture and lamp

exactly.

Do not remove or insert lamp when

power is on.

Do not scratch glass or subject lamp to

undue pressure as either may cause

lamp breakage.

Protect operating lamp from sources

of moisture.

Symptom

LAMP FAILS TO
LIGHT





LAMP GOES OUT
AFTER LIGHTING

LAMP CYCLES

ON AND OFF

Possible Cause


·

Circuit feeding the fixture not energized

· Wiring error in circuit or module connection

· Faulty lamp

· Line or ballast output

· Faulty ballast

· Ambient temperature too low

· Faulty lamp


· Lamp wattage too high

· Ballast output voltage low

Corrective Action


· Check circuit breaker or fuse to ensure that circuit is energized.

· Examine fixture splice box to ensure that connections are correct.

· Remove the faulty lamp and substitute another lamp, preferably one that

is known to light. If the lamp lights, replace the original with a new one.

· Check line voltage at fixture. Check open circuit voltage.

· Check circuit continuity.

· Check ballast rating against existing environmental conditions.


· Occasionally a lamp will exhibit this symptom rather than simply

failing to light. Substitute a new lamp.


· Install lamp wattage specified in housing.

· Check line voltage at the fixture. Check open circuit voltage.

Part No. CJ52006