Important safety information, Save these instructions, Installation instructions – Gotham DLV TRIM FINISH TRIM CJ520343 Manuel d'utilisation
Page 3: Dlv trim" finish trim installation, New installation

INSTALLATION INSTRUCTIONS
"DLV TRIM"
FINISH TRIM INSTALLATION
Part No. CJ520343
Upon receipt, thoroughly inspect for any freight
damage which should be brought to the attention
of the delivery carrier. Compare the catalog
description listed on the packing slip with the
label on the carton to ensure you have received
the correct merchandise.
IMPORTANT SAFETY
INFORMATION
(
For Your Protection, Read Carefully
)
1.
Electric current can cause painful shock or
serious injury unless handled properly. For your
safety, always remember the following:
- Turn off the power supply.
- Ground the fixture to avoid potential electrical
shocks.
- Do not handle an energized fixture with wet
hands, when standing on a wet or damp surface,
or in water.
- Double check all electrical connections to be sure
they are tight and correct
2.
Specific safety information concerning lamps:
- Match wattage of fixture and lamp exactly.
- Do not remove or insert lamp when power is on.
- Do not scratch glass or subject lamp to undue
pressure as either may cause lamp breakage.
Protect operating lamp from sources of moisture.
Figure 1
Figure 2
NEW INSTALLATION
DLV DWN 4 TRIM INSTALLATION
1.
Install lamp (A) into lamp holder (B) with safety glass (C)
installed in front of lamp (when provided). Refer to Figure 1.
Install assembly on top of trim utilizing three springs to
secure. Refer to Figure 2.
2.
Connect socket from fixture housing to the lamp/lamp holder
assembly completed in Step #1. Refer to Figure 3.
3.
Install the cone by squeezing the butterfly springs and
engaging them into the slots provided in the housing. When
both springs are engaged, gently push the assembly up and
the springs will secure. Refer to Figure 4.
4.
Clean fingerprints from assembly and test. Installation is
complete.
DLV ADJ 4 TRIM INSTALLATION AND ADJUSTMENT
1. Feed socket in housing through round hole in adjusting
mechanism above the ceiling aperture opening.
Refer to Figure 5.
2. Install lamp (A) into lamp holder (B) with safety glass (C)
installed in front of lamp (when provided). Refer to Figure 1.
Install assembly through the housing aperture into the three
springs provided on the adjusting mechanism.
Refer to Figure 5.
3. Rotate and adjust to desired angle (up to 45° elevation and
360° rotation) and lock using thumb screws. Rotation lock
(D); elevation lock (E). Refer to Figure 6.
4. Install the cone by squeezing the butterfly springs and
engaging them into the slots provided in the housing. When
both springs are engaged, gently push the assembly up and
the springs will secure. Refer to Figure 4.
5. Clean fingerprints from assembly and test installation is
complete.
DLV WSH and 1″-3″ ADJ/DWN TRIM INSTALLATION
1. Install lamp (A) into lamp holder (B) with safety glass (C)
installed into front of lamp (when provided).
Refer to Figure 1.
2. Install lamp holder into bracket on trim. Lock with thumb
screw (F). Refer to Figure 7. Adjust to angle desired (on ADJ
trims only) and lock with thumb screw (G). Refer to Figure 8.
3. To adjust rotation for WSH and ADJ trims, adjust rotation and
lock with thumb screw (D). Refer to Figure 6. For WSH trims,
rotate trim to proper orientation with wall. Refer to Figure 9.
Connect socket from fixture housing to the lamp/ trim
assembly.
4. Install the cone by squeezing the butterfly springs and
engaging them into the slots provided in the housing. When
both springs are engaged, gently push the assembly up and
the springs will secure. Refer to Figure 4.
5. Clean fingerprints from assembly and test. Installation is
complete.
Figure 3
Figure 4
Figure 5 Figure 6
Figure 7
Figure 8
Figure 9
TROUBLE SHOOTING CHART
Check first for any visible damage to the lamp or frame-in module. If they seem in good condition, locate the problem
in the following list for possible cause and corrective action.
POSSIBLE CAUSE
CORRECTIVE ACTION
LAMP FAILS TO LIGHT
• Circuit feeding the fixture not energized
• Wiring error in circuit or module connection
• Faulty lamp
• Check circuit breaker or fuse to insure that circuit is energized.
• Examine fixture splice box to see that connections are proper.
• Remove the faulty lamp and substitute another lamp, preferably
one that s known to light I f the lamp, replace the original with a
new one.
LAMP GOES OUT AFTER LIGHTING
•
Faulty lamp
• Occasionally a lamp will exhibit this symptom rather than simply
failing to light. Substitute a new lamp.
LAMP CYCLES ON AND OFF
•
Insulation is too close to fixture
• Lamp wattage too high
•
Remove insulation from around module (at least 3″).
• Install lamp wattage specified in housing.
SAVE THESE INSTRUCTIONS
CJ520343 Rev. B 2/2014
WARNING - RISK OF FIRE. DO NOT INSTALL
INSULATION WITHIN3 INCHES OF FIXTURE
SIDES OR WIRING COMPARTMENT, NOR
ABOVE FIXTURE IN SUCH A MANNER AS TO
ENTRAP HEAT.