This device complies with Part 15 of the
FCC Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference,
and (2) this device must accept any
interference

received,

including

interference that may cause undesired
operation.

CJ5201026 Rev. E

11/2013 2 of 6

©2010 Acuity Brands Lighting, Inc.

All Rights Reserved.

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

EVO CYL

LED CYLINDERS

Upon receipt, thoroughly inspect for any
freight damage which should be brought to
the attention of the delivery carrier. Compare
the catalog description listed on the packing
slip with the label on the carton to ensure you
have received the correct merchandise.

Figure 4

SURFACE MOUNTED CYLINDER:

1. Remove trim assembly by pulling down on reflector as shown in Figure 1. Carefully disengage constant

tension spring from screw located in top of heatsink. Carefully allow the spring to retract back into cylinder.
USE EXTREME CAUTION WHEN RETRACTING THE CONSTANT TENSION SPRING. SPRING IS UNDER
TENSION AND EDGES ARE SHARP. GLOVES ARE REQUIRED.

2. Remove twist-lock hinge cover plate from top of cylinder housing by releasing the twist-lock lever inside the

cylinder as shown in Figure 2. Reinstall trim assembly once cover plate has been removed.

3. Attach the twist-lock hinge cover plate directly to 4” square or octagonal junction box as shown in Figure 3

using (2) Phillips head screws provided.

4. Install the cylinder housing onto the twist-lock hinge cover plate by guiding the “T” through the hole in the top

of the cylinder as shown in Figure 4.

5. Align “T” perpendicular to hole and engage into the two small slots. Allow cylinder housing to hang from twist-

lock hinge cover plate.

6. Make supply connections. Supply wire must meet local or national codes and be rated for a minimum of

75

0

C. Push completed supply connections through hole in twist-lock hinge cover plate and into junction box..

7. Swing cylinder housing flush to the ceiling against the twist-lock hinge cover plate. Grasp the cylinder housing

with both hands and rotate the entire housing clockwise until the internal locking mechanism snaps into place
as shown in Figure 6. There will be an audible “click” when the locking mechanism is fully engaged.

8. If necessary, clean reflector with a non-abrasive cleaner to remove dirt, fingerprints, etc. It is recommended

that reflector be cleaned periodically to retain optimum photometric performance.

Figure 3

Figure 2

Figure 1

Figure 6

Figure 5

Twist-lock

lever

IMPORTANT SAFETY INFORMATION

For Your Protection, Read Carefully

Warning: Risk of fire. Do not install
insulation within 3 inches of fixture
sides or wiring compartment, nor above
fixture in such a manner as to entrap
heat.

Electric current can cause painful
shock or serious injury unless handled
properly. For your safety, always
remember the following:

• Turn off the supply power.
• Ground the fixture to avoid potential
electrical shocks.
• Do not handle an energized fixture or
energize any fixture with wet hands,
when standing on a wet or damp surface,
or in water

Advertising