4. Installation
Connect the first floor to the power supply
(100 ~ 240 VAC, 50 ~ 60 Hz). Connect the
power output of the floor to the power input
of the next floor.
Connect the DMX output from the
controller to the DMX input of the first floor.
Connect the DMX output of the floor to the
DMX input of the next floor.
Connect a maximum of 50 floors.
Fix two floors as illustrated on the right.
5. Use
Refer to page 2 for a complete overview of the menu.
Control Panel
Enter and quit the menu with MENU, move through the menu and set the values with the arrows, confirm with
ENTER.
Manual Mode
1
Red dimmer
2
Green dimmer
3
Blue dimmer
Auto Mode
1
Flash
2
Automatic fade in and fade out
3
Automatic 7-colour change
4
Chasing lights
5
Chasing speed