Report receive to transmit delay, Codes de défaut – VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) standpipe ver. Modbus and Levelmaster protocol Manuel d'utilisation
Page 61
Advertising

61
11 Annexe
VEGAPULS 62 version tube guide d'ondes • Protocole Modbus et Levelmaster
41363-FR-121120
Response:
Paramètres
Length
Code/Data
Set Receive to Transmit Delay
5 characters ASCII
UuuFn
n = number of measurement values
(0, 1 or 2)
Report Receive to Transmit Delay
Request:
Paramètres
Length
Code/Data
Report Receive to Transmit Delay
4 characters ASCII
UuuR
Response:
Paramètres
Length
Code/Data
Report Receive to Transmit Delay
7 characters ASCII
UuuRmmm
mmm = milliseconds (50 bis 250),
default = 127 ms
Codes de défaut
Error Code
Name
EE-Error
Error While Storing Data in EEPROM
FR-Error
Erorr in Frame (to short, to long, wrong data)
LV-Error
Value out of limits
Advertising