Technical characteristics, Installation – Candy P 700__1 SP CX Manuel d'utilisation
Page 14

23
TECHNICAL CHARACTERISTICS
* Some models only ** Manufacturer setting
GB cat. II
2H3 +
Cooking hobs 70x50
Burners
5 gas
5 gas
5 gas
5 gas
5 gas
5 gas
–
–
–
–
–
–
Reference type
P751
P751
P751
P752
P752
P752
Supply Voltage
(V/Hz)
220-240/50
220-240/50
220-240/50
220-240/50
220-240/50
220-240/50
Installed electric power
(W)
–
–
–
–
–
–
Medium burner
1
1
1
1
1
1
Large burner
2
2
2
2
2
2
Small burner
1
1
1
1
1
1
Double ring burner
1
–
–
1
–
–
Maxi burner
–
1
–
–
1
–
Fish burner
–
–
1
–
–
1
Power of gas installed:
- G20/20 mbar (kW)**
11,2
11,2
11,2
11,2
11,2
11,2
- G30/28-30 mbar (g/h)
813
813
813
813
813
813
Electric ignition*
yes
yes
yes
yes
yes
yes
Gas safety device
–
–
–
yes
yes
yes
Product size
mm.
695x510
695x510
695x510
695x510
695x510
695x510
Degree protection
–
–
–
–
–
–
Class
3
3
3
3
3
3
Cooking hobs 90x50
Burners
5 gas
5 gas
5 gas
4 gas
5 gas
5 gas
5 gas
4 gas
–
–
–
1 electric
–
–
–
1 electric
Reference type
P505
P505
P505
P505
P506
P506
P506
P506
Supply Voltage
(V/Hz)
220-240/50 220-240/50 220-240/50 220-240/50 220-240/50 220-240/50 220-240/50 220-240/50
Installed electric power
(W)
–
–
–
1850
–
–
–
1850
Medium burner
1
1
1
1
1
1
1
1
Large burner
2
2
2
2
2
2
2
2
Small burner
1
1
1
1
1
1
1
1
Double ring burner
1
–
–
–
1
–
–
–
Maxi burner
–
1
–
–
–
1
–
–
Fish burner
–
–
1
–
–
–
1
–
Power of gas installed:
- G20/20 mbar (kW)**
11,2
11,2
11,2
7,9
11,2
11,2
11,2
7,9
- G30/28-30 mbar (g/h)
813
813
813
575
813
813
813
575
Electric ignition*
yes
yes
yes
yes
yes
yes
yes
yes
Gas safety device
–
–
–
–
yes
yes
yes
yes
Product size
mm.
860x510
860x510
860x510
860x510
860x510
860x510
860x510
860x510
Degree protection
–
–
–
Type Y
–
–
–
Type Y
Class
3
3
3
3
3
3
3
3
Fig. 1
Fig. 1
24
INSTALLATION
The Purchaser is responsible for the installation of the hob. The Manufacturer does not
accept any responsibility for any damage or loss resulting from incorrect installation, and
as such this will not covered by the Manufacturer’s Guarantee.
The hob may be installed in any worktop which is heat resistant to a temperature of 100°
C, and has a thickness of 25 - 40 mm. The dimensions of the insert to be cut out of the
worktop are in shown in Fig. 1.
If the Hob is fitted next to a cabinet on either side,
the distance between the Hob and the cabinet mu-
st be at least 150 mm (see Fig. 2); while the di-
stance between the hob and the rear wall must be
at least 55 mm.
If below the Hob there is an accessible space, the-
re must be a partition panel in insulating material
(wood or similar) providing a space of at least 10
mm below the Hob (see Fig. 2).
The Hob unit is fitted by attaching the Fixing
Clamps supplied, using the holes at the base of
the unit.
VERY IMPORTANT - APPLYING THE SEALANT
Important - The diagram below shows how the sealant should be applied.
This appliance has been designed for non-professional, i.e. domestic, use.
Appropriate checks and tests have ensured that, even in the most extreme conditions,
the temperatures reached are within acceptable limits. The Hob is thermally insulated
(in line with Regulation EN) and may be installed: next to panels higher than the
worktop, for type «Y», or next to panels not higher than the worktop for type «X».
See technical characteristics table «Degree of protection».
Fig. 2
Partition panel
150 mm
min.
30 mm
10 mm