Advanced Settings and Read-Out

Press both the UP (

) and DOWN (

) buttons together

for 3 seconds. "INFO" is displayed.

Press the UP (

) button until you reach the desired sub

menu. Select the sub menu with the OK ( ) button.

Monitoring energy consumption

The thermostat calculates the average time it has been
switched on allowing you to monitor your energy con-
sumption. The thermostat displays the total switch-on
time as a percentage for the last 2 days, 30 days or 365
days.

Calculation of operational costs per day:
(switch-on time:100) x kW x kWh-price x 24 h per day

Example:
Read-out: 30% in the latest 365 days
Size of heating system: 1.2 kW (ask the installer)
Cost of power: 0.2 USD/ kWh - Calculation:
(30:100) x 1.2 kW x 0.2 USD/ kWh x 24 h = 1.7 USD per day

Press the UP (

) or DOWN (

) button to show the dif-

ferent readouts.

No changes can be made here. Use the OK ( ) button to
end.

4-event sequence

The present event sequence flashes: Days 1-5, followed by
days 6-7. To change, press the UP (

) button until you

have days 1-6 and then day 7 flashing, or all 7 days are
flashing. Select the required sequence with the OK ( )
button.

5-2:

4 events in 5 days +
2 events in 2 days.

6-1:

4 events in 6 days +
2 events in 1 day

7-0:

4 events in 7 days

Maximum and minimum allowed temperature range

The temperature setting range of 41˚F to 104˚F can be
limited to prevent a too high or too low temperature from
being selected.

Set the maximum allowed temperature.
Use the UP (

) or DOWN (

) button to

increase or reduce and the OK ( ) button
to accept.

Next "LoLi" is displayed.

Press the OK ( ) button to continue.

Set the minimum temperature that the

floor should never fall below. Use the UP

(

) or DOWN (

) button to increase or

reduce and the OK ( ) button to accept.

Note: It is possible to select the heating OFF as your "LoLi" setting by
reducing the setting to 41˚F, and then pressing the (

) once more.

Time and temperature scale selection

You can select either ˚F˚ or C scale, and 12 or 24 hour
clock as follows:

Press the UP ( ) or DOWN
( ) button to change settings.
Confirm the required scale
with the OK ( ) button.

Adaptive function

This function enables the thermostat to calculate when it
needs to switch ON so that the required temperature is
reached at the set time. With a start time of 7:00 a.m.
therefore, the thermostat may switch ON as early as 6:00
a.m. so that the desired temperature of 77˚F is achieved
by 7:00 a.m. Without this function set, the thermostat will
start to heat at the time you set.

Press the DOWN (

) button to switch

between on and off.

Press the OK ( ) button to confirm.

Ending the programming sequence

Press the OK ( ) button to end programming and to
return to scheduled program.

2 days
30 days
365 days
Software version
Temperature sensor

QuickStat Installation & Operation Manual