20w/6ohm x2, Sum2 – Nuvo NV-I8GMS Manuel d'utilisation
Page 30

Grand Concerto
Control Pad
MENU
OK
Modern Rock
Drift-Follow The Day
Living For
iPod
3:09 pm
LOCAL SOURCE
SWITCH
NV-LSI24
CONNECT TO
AMPLIFIER
RLY+
RLY-
L-
L+
R-
R+
T
o
A
m
p
lif
ie
r
To Keypad
T
o
S
p
e
a
k
e
rs L-
L+
R-
R+
Model NV-LSI24
Mute Interface Module
R
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
SYS ON
EXT. MUTE
L
R
L
R
L
R
VARIABLE
OUTPUT
FIXED
OUTPUT
SUM1
3033118
C
US
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
NuVo Technologies Cincinnati Ohio USA
FUSE:T5 A
120V 60Hz 500W
MODEL NV-I8DM
SIX SOURCE EIGHT ZONE
AUDIO DISTRIBUTION SYSTEM
www.nuvotechnologies.com
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
1
2
3
RS-232
CONNECT TO
NV-I8X
USE NV-SLC1
CABLE
CONNECT TO
NV-I8X
USE NV-SLC1
CABLE
CONNECT TO
NV-I8EZP1
USE NV-NC1
CABLE
USE CNLY WITH 250V FUSE
4
5
6
SUM2
5
6
7
8
OUTPUT POWER
20W/6OHM X2
ZONE 6
ZONE 6
ZONE 7&8
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
6
4
5
3
1
2
SOURCE STATUS INPUTS
The connection from the LSI24 is made
through the NV-IG8LSA RJ-45 port on the
back of the Control Pad terminated with
standard 568A. The connection at the LSI24
requires the use of the Brown lead for
positive and Brown Stripe for negative.
NV-I8GLSA
NuVoNet
28
NV-LSI24 Local Source Interrupt (fig. 17)
The Local Source Interrupt enables an amplified local audio source to override the Grand Concerto System and play through the
local zone in-wall speakers. The most common scenario for this is a television that would benefit from higher-quality speakers.
The back of the Grand Concerto Control Pad has two Cat-5 inputs. One is labeled NuVoNet and is the Cat-5 that runs to the EZ Port
at the head end. The other is labeled NV-I8GLSA. This is intended to react to the LSI24 accessory. It requires an RJ-45 connection
at the Control Pad end and the Brown-and-Brown-Stripe pair as a voltage trigger.
Note that the Local Source Interrupt is a passive non-amplified device. The signal sent to it must be amplified.