Installation – Napoleon Fireplaces 1600C-1 Manuel d'utilisation

Page 5

Advertising
background image

5

INSTALLATION

For reduced clearances installation must comply with

NFPA 211or CAN/CSA-B365.
For clearances when installed with blower kit EP63, refer

to page 6.

Alcove installation

Model 1600C-1 may be installed into an alcove having a

depth of not more than 4 feet and a height of at least 7 feet,

when using a listed double wall connector that is rated for a

minimum 12” clearance to combustible material.

The minimum clearances are as shown.

Stove installation

If the stove is to be installed on a

combustible floor, it must be

placed

on

a

approved

non-combustible hearth pad,

that extends 8" (200mm)

beyond the stove sides and

back, and 18" (455mm) to the

front.

Listed single wall chimney connector

Flue configuration

Type 1

Horizontal

Vertical

FROM

UNIT

A

16”

16”

B*

22”

22”

C

15”

15”

FROM

PIPE

D

25”

25”

E

...

22”

* A 22 in. Minimum clearance must be maintained from

combustible wall to the chimney connector.

Double walled connectors listed for a minimum

clearance of 12” or less from combustible materials

must be used to achieve the following clearances.

Flue configuration

Type 2

Horizontal

Vertical

FROM

UNIT

A

16”

16”

B

14”

14”

C

15”

15”

FROM

PIPE

D

25”

25”

E

...

16”

2 2 "

1 6 "

1 6 "

4 f o o t m a x

Alcove installation

Walls shall not extend from front of unit when installed

in the alcove configuration.

8 "

1 8 "

8 "

8 "

A

B

D

C

C

E

8 4 "

I l l u s t r a t e d w i t h . 7 5 " h e a r t h p a d .