Lennox Hearth ELITE VISN-25/35 Manuel d'utilisation
Page 14

14
Vent Parts List
Secure Vent™ directvent pipe by Security Chimneys™* may be used with
this appliance. Please see the lists below to verify the components avail
able from each directvent pipe manufacturer. Snorkel terminations are
available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
Security - Secure Vent 6-5/8”x 4” Pipe
Part Number
Description
SV4LC
6” Pipe Length
SV4L12
12” Pipe Length
SV4L24
24” Pipe Length
SV4L36
36” Pipe Length
SV4L48
48” Pipe Length
SV4LA
6” Pipe, Adjustable
SV4LA12 12” Pipe, Adjustable
SV4FA
Flashing, 1/12 to 6/12 Roof Pitch
SV4FB
Flashing, 7/12 to 12/12 Roof Pitch
SV4RSM
Wall Radiation Shield
SV4E46
45º Elbow
SV4E90
90º Elbow
SV4VS
Vinyl Shield Protector
SV4FC
Storm Collar
SV4CGV
Vertical Termination Cap
SV4BF
Firestop
SV4CHC
Horizontal Termination Cap
SV4STC36
Snorkel Termination Cap (36”)
SV4STC14
Snorkel Termination Cap (14”)
SV4BM
Wall Band
Simpson DuraVent GS 65/8”x 4” Pipe
Part Number
Description
908
6” Pipe Length
907
9” Pipe Length
906
12” Pipe Length
904
24” Pipe Length
903
36” Pipe Length
902
48” Pipe Length
911
11” to 145/8” Pipe, Adjustable
942
Wall Thimble
940
Rnd Support Box/Wall Thimble Cover
941
Cathedral Ceiling Support Box
943
Flashing, 0/12 to 6/12 Roof Pitch
943S
Flashing, 7/12 to 12/12 Roof Pitch
945
45º Elbow
990
90º Elbow
950
Vinyl Siding Standoff
953
Storm Collar
963
Ceiling Firestop
988
Wall Strap
981
Snorkel Termination (36”)
982
Snorkel Termination (14”)
984
Horizontal Termination Cap
985
Horizontal Termination Cap (High Wind)
980
Vertical Termination Cap
991
Vertical Termination Cap (High Wind)
Horizontal Vent Installation
Venting terminals may not be recessed into a wall or siding.
1) Set the unit in the desired location. Check whether or not wall studs
are in the way when the venting system is attached. If wall studs are
in the way, you may want to adjust the location of the unit.
2) Assemble the desired combination of pipe and elbow to the appliance
adaptor with pipe seams facing down. Offsetting the pipe seams as
double seams in one place will cause the outer pipe to take an oval
shape. The Horizontal Termination Kit comes with 18” of straight vent
65/8” black outer pipe and 4” inner vent.
3) With the pipe attached to the stove, slide the stove into its correct
location and mark the wall to the dimensions of the wall thimble
(91/4” x 101/4”). The center of the round hole should line up with
the centerline of the horizontal pipe. (91/4” is sidetoside dimen
sion and 101/4” is vertical dimension) If the wall being penetrated
is constructed of non combustible material (i.e. masonry block or
concrete), a 7” diameter hole is acceptable.
4) The horizontal run of vent should have a 1/4” rise for every 1 foot of
run toward the termination. Never allow the vent to run downward.
This could cause high temperatures and may present the possibility
of a fire.
5) The location of the horizontal vent termination on an exterior wall must
meet all local and national building codes and must not be blocked
or obstructed. For External Vent Termination Locations, see Page 17.
Snorkel Terminations:
For installations requiring a vertical rise on
the exterior of the building, 14inch (356 mm) and 36inch (914 mm) tall
Snorkel Terminations are available, as well as the standard Riser Vent.
Follow the same installation procedures as used for standard Horizontal
Termination. NEVER install the snorkel upside down.
Typical parts needed for a horizontal installation.
14” Snorkel for Vision 35
Standard Horizontal for Vision 25
Wall Thimble
Decorative Wall Trim
Pipe Length
max
min
Snorkel required for Vision 35 or
Vision 25 if horizontal run
exceeds 3 feet.
Figure 15