SYMPTOM POSSIBLE

CAUSE

REMEDY
to clamp connection

Wrong size contact tip

Use proper tip

Low primary voltage

Have primary voltage checked by
electrician

Too long or improper extension
cord

See instruction under extension
cord use

Wrong type or size of wire

Check manual for proper wire size
or type

Wall receptacle improperly wired

Consult electrician

Wrong welding polarity

Change to proper polarity

Faulty gun assembly

Replace gun

No wire feed but arc works

Faulty wire speed switch

Replace wire speed switch

Faulty main circuit board

Replace main circuit board

No tension on drive roller

Adjust drive tension

Liner plugged

Replace liner

Faulty drive motor (extremely rare)

Replace drive motor

Wire birdnesting at drive roller

Too much tension on drive roller

Adjust drive tension (see manual)

Wrong size contact tip

Use correct size contact tip

Gun liner worn or damaged

Replace liner

Contact tip is clogged or damaged

Replace contact tip

Liner stretched or too long

Trim liner to proper length

Wire burns back to contact tip

Gun liner worn or damaged

Replace liner

Liner stretched or too long

Trim liner to proper length

Wrong size contact tip

Use correct size contact tip

Contact tip is clogged or damaged

Replace contact tip

Drive tension not set properly

See instruction on setting drive
tension

Gun nozzle arcs to work surface

Slag buildup inside nozzle or nozzle
shorted

Clean or replace nozzle as needed

Ground clamp or cable gets hot

Bad connection from cable to clamp

Tighten connection or replace cable