TROUBLESHOOTING

The following section lists some basic troubleshooting types should you encounter issues when using your Monster
Power Amplifier.

Symptom

Possible Cause

Remedy

Amplifier Does Not
Turn On

Power Cord Disconnected

Check power cord and connect to AC Line

Blown Power Fuse

Check Main power fuse on back of amplifier.
Disconnect amplifier from AC before removing fuse.
Replace with same value fuse only.

Preamp Remote Trigger Cable Not Connected to
Receiver or Preamplifier.

Verify that the remote trigger cable is connected to
both the amplifier and the receiver or preamplifier.

Remote Trigger Out from Receiver or Preamplifier Is
Incorrect Voltage.

Remote trigger in requires 3-30 V AC/DC to turn
amplifier ON. If the output of the receiver or
preamplifier remote trigger is not within this range,
the amplifier will not turn on.

No Sound from
One or More
Channels/ “000”
showing on one or
more Meters

Input Type Selection switch is set to the incorrect
input type.

Verify that all of the Input Type selection switches
are in the correct positions. If using standard
RCA connections, the switch should be set to
Unbalanced. If using XLR connections, the switch
should be set to

Balanced.

Input From Receiver or Preamplifier is Not Connected. Check Input connections