Installation & operation, Filling the compressor with oil, Oil changes – Makita MAC5500G Manuel d'utilisation

Page 6: Engine lubrication, Maintenance

Advertising
background image



InStALLAtIOn & OPERAtIOn

OthER APPROvED OILS.

Regular mineral oils can also be used in Makita compressors. Always

use a non-detergent oil with the following specifications:

AMbIEnt tEMPERAtuRES At

POInt Of OPERAtIOn

SAE vISCOSIty

ISO vISCOSIty

-16°C TO 0°C (3.2°F - 32°F)

SAE 10W

ISO 32

1°C TO 26°C (33.8°F - 78.8°F)

SAE 20W

ISO 68

ABOVE 27°C (80.6°F)

SAE 30W

ISO 100

fILLInG thE COMPRESSOR wIth OIL

1) Remove the oil filler plug
2) Slowly pour the proper oil into the pump crankcase.
) Always keep oil level in the middle of the sight glass.

OIL ChAnGES

CHANGE OIL EVERY 300 HOURS OR 3 MONTHS

WHICHEVER COMES FIRST.

1) Remove the oil drain plug. Allow oil to drain completely.
2) Replace the oil drain plug.
) Refill with the recommended oil to the proper level.

InItIAL OIL ChAnGE DuE At 100 hOuRS.

EnGInE LubRICAtIOn

Check engine Owner’s manual for lubrication and maintenance

requirements.

MAIntEnAnCE

Before doing any maintenance or adjustments to your air compressor,

the following safety precautions should be taken:

TURN OFF ENGINE. WAIT UNTIL ENGINE IS COMPLETELY

STOPPED.

DRAIN AIR RECEIVER AND AIR LINES OF AIR PRESSURE.