Accessing programming mode parameters – Motorola CP125TM Manuel d'utilisation
Page 22

20
English
PROG
RAMM
ING
MODE
ACCESSING PROGRAMMING MODE PARAMETERS
Press the PTT button or the preprogramed Monitor button to scroll through the features available in
Programming Mode. Press the
!"
buttons to scroll through the parameters for each feature.
Feature
Range
Remarks
Squelch Level
(SQL-XX)
SQL-00, …, SQL-15
Select low level when you need to receive very
weak
signal, and select high level when the
communications distance is near.
Time Out Timer
(TOT-XXX)
TOT-OFF, TOT-001, …, TOT-010
This determines the maximum duration (in
minutes) that you can transmit continuously.
Scan List 1
(SCANLST1)
1-01-XXX, …,
1-16-XXX,
XXX denotes channel number.
Up to 16 members per scan list. First member is
assigned as Priority Channel, if Priority Scan is
started. When scanning is started, only these 16
members will be scanned.
Battery Saver
(BS-XXXX)
BS-OFF,
BS-NORM,
BS-ENH
Battery Saver helps to extend your battery life.
When enabled, it turns off radio receiver circuitry
periodically when no activity is detected. BS-
NORM (Normal) turns off the radio less
frequently; select this if you want to save battery,
but expect a Selective Call. BS-ENH (Enhanced)
turns off the receiver for a longer duration; select
this if you want to maximize battery saving and
do not expect to receive any Selective Call.
Battery Type
(BT-XXXX)
BT-NIMH,
BT-NICD,
BT-ALK
Selects the type of battery that your radio uses:
NIMH (Nickel Metal Hydride), NICD (Nickel
Cadmium) or ALK (Alkaline).
05_Programming.fm Page 20 Monday, August 22, 2005 1:49 PM