Installation preparation – electrical supply, Prepare electrical wiring – GE 206C1559P195 Manuel d'utilisation

Page 5

Advertising
background image

#282 French

The improper connection of the equipment-

grounding conductor can result in electric

shock. Check with a qualified electrician or

service representative if you are in doubt that

the appliance is properly grounded.

Do not modify the plug provided with the

appliance; if it will not fit the outlet, have

a proper outlet installed by a qualified

technician.

WARNING

5

Cabinet Preparation and Wire Routing

• The wiring may enter the opening from either side,

rear or floor within the shaded area illustrated

above in Figure E and defined in Figure A.

• Cut a 1-1/2" maximum diameter hole to insert the

electrical cable. Permanent wiring connections

may pass through the same hole as the drain

hose and hot water line, if convenient. Hole edges

must be smooth and rounded. If the cabinet wall is

metal, the hole edge must be covered with a cord

protector.

NOTE: Power cords with plug must pass through a

separate hole.

PREPARE ELECTRICAL WIRING

Electrical Requirements

• This appliance must be supplied with 120V, 60 Hz.,

and connected to an individual properly grounded

branch circuit, protected by a 15- or 20-ampere

circuit breaker or time-delay fuse.

• Wiring must be 2 wire with ground.

• If the electrical supply does not meet the above

requirements, call a licensed electrician before

proceeding.

Grounding Instructions – Permanent Connection

This appliance must be connected to a grounded-

metal, permanent wiring system, or an equipment-

grounding conductor must be run with the circuit

conductors and be connected to the equipment-

grounding terminal or lead on the appliance.

Grounding Instructions – Power Cord Models

This appliance must be grounded. In the event of a

malfunction or breakdown, grounding will reduce

the risk of electric shock by providing a path of

least resistance for electric current. This appliance

is equipped with a cord having an equipment-

grounding conductor and a grounding plug. The plug

must be plugged into an appropriate outlet that is

installed and grounded in accordance with all local

codes and ordinances.

661Dia56A

White

18"

6"

24"

from Wall

3"

from

Cabinet

Alternate

Receptacle

Location

Ground

Black

1-1/2" Dia. Hole (Max.)

18"

6"

Receptacle

Location

Area

Figure E

Installation Preparation – Electrical Supply

#282 French

WARNING

FOR PERSONAL SAFETY: Remove house fuse

or open circuit breaker before beginning

installation. Do not use an extension cord or

adapter plug with this appliance.

Electrical Connection to Dishwasher

Electrical connection is on the right front of

dishwasher.

• For permanent connections, the cable must be

routed as shown in Figure E. The cable must extend

a minimum of 24" from the rear wall.

• For power cord connections, install a 3-prong

grounding-type receptacle in the adjacent cabinet

rear wall, between 6" and 18" from the opening, 6"
to 18" above the floor as shown in Figure E.

Hole Diameter

1-1/2" Maximum

Cord

Protector

(Provided

with Power

Cord Models Only)

Metal Cabinet

Wall

#282 French

ADVERTENCIA

PARA SEGURIDAD PERSONAL: Retire el

fusible de la casa o abra el interruptor de

circuitos antes de empezar la instalación.

No use un cable de extensión o enchufe

adaptador con este aparato.

#282 French

#282 French

ADVERTENCIA

La conexión incorrecta del conductor

de conexión a tierra del equipo puede

resultar en choque eléctrico. Consulte con

un electricista calificado o representante

de servicio si tiene dudas de la conexión

a tierra del aparato. No modifique el

enchufe que se suministra con el aparato;

si no calza en el tomacorrientes, haga

que un técnico calificado le instale un

tomacorrientes adecuado.

#282 French

Advertising