Maintenance, Specifications, Operating instructions – Desa 125-R Manuel d'utilisation

Page 7

Advertising
background image

www.desatech.com

114248-01B

7

SHUTTING OFF HEATER

• For short periods of time, turn the main burner

off by turning control knob clockwise to the

PILOT position.

• For extended periods of non use, turn appli-

ance completely off by turning control knob

clockwise to the PILOT position, press knob

slightly, then turn knob fully clockwise to

the OFF position. Note: For propane/LP gas

models, also turn off gas supply cylinder.)

PILOT BURNER ADJUSTMENT

1. Remove pilot adjustment cap. The pilot adjust-

ment cap is a slotted screw located in front

of the PILOT designation stamped on top of

valve body just below control knob.

2. Adjust pilot key to provide properly sized

flame. Rotate the key clockwise to decrease

flame or counterclockwise to increase flame.

3. Replace pilot adjustment cap.

MAINTENANCE

WARNING:

• Never attempt to service

heater while it is connected to

propane supply, operating or

hot. Severe burns can occur.

• Keep heater clear and free

from combustible materials,

gasoline and other flammable

vapors and liquids.

• Do not block the flow of com-

bustion or ventilation air.

1. Keep heater clean. Clean heater annually or as

needed to remove dust and debris. If heater is

dirty or dusty, clean heater with a damp cloth.

Use household cleaners on difficult spots.

2. Inspect heater before each use. Check connec-

tions for leaks. Apply mixture of liquid soap

and water to connections. Bubbles forming

show a leak. Correct all leaks at once.

3. Inspect hose/regulator assembly before each

use. If hose is highly worn or cut, replace.

4. Have heater inspected yearly by a qualified

service agency.

OPERATING

INSTRUCTIONS

Continued

SPECIFICATIONS

Propane/LP Model 125-R
Rating

125,000 Btu/Hr (131,882 kj)

Fuel

Propane Vapor Only

Fuel Consumption per Hour

5.17 liters (1.3 gallon)

2.6 kg (5.8 pounds)

Supply Pressure To Regulator (for input adjustment)

Maximum

1380 kPa (200 psi)

Minimum

138 kPa (20 psi)

Manifold Pressure 2.3 kPa (9.5 inches W.C.)
Weight

Heater

17.69 kg (39 lbs)

Shipping

20.86 kg (46 lbs)

Size - L x W x H

40.6 x 45.7 x 109.2 cm

(16 x 18 x 43 inches)

Min Temperature

-29 °C (-20° F) Surrounding

Air Temperature

Natural Gas Model 125-RN
Rating

125,000 Btu/Hr (131,882 kj)

Fuel

Natural Gas Only

Fuel Consumption

per Hour

3.5 m

3

(125 ft

3

)

Manifold Pressure 1.5 kPa (6 inches W.C.)
Weight

Heater

17.69 kg (39 lbs)

Shipping

20.86 kg (46 lbs)

Size - L x W x H

40.6 x 45.7 x 109.2 cm

(16 x 18 x 43 inches)

Min Temperature

-29 °C (-20° F) Surrounding

Air Temperature

Advertising